Language
EN
Language open
Arslan Metal offers Sheet Lead for many applications that include Radiation Shielding - laboratories, hospitals, dental offices and veterinary clinics, Construction – flat and pitched roofing, mosques roofing, clading, flashing and waterproofing, gutters, parapets, Corrosion Protection - acid Storage and handling - autoclaves movable lead screens sound barriers and sound proofing, tank lining vibration absorbers and all lead detail work. They are produced that Lead fluid is casting to the moulds and follows to the rolling machines,to be lead sheets.

Dimensions Table For Lead Sheet


Thickness
12" x 24"
(1Ft x 2Ft)
300 x 600mm
12" x 36"
(1Ft x 3Ft)
300 x 900mm
12" x 48"
(1Ft x 4Ft)
300 x 1200mm
12" x 60"
(1Ft x 5Ft)
300 x 1500
12" x 72"
(1Ft x 6Ft)
300 x 1800mm
12" x 84"
(1Ft x 7Ft)
300x 2000mm
12" x 96"
(1 Ft x 8Ft)
300 x 2400mm
inch mm Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2
1/32 0.8 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07
5/128 1.0 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34
3/64 1.2 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61
1/16 1.6 3,72 18,14 3,72 18,14 3,72 18,14 3,72 18,14 3,72 18,14 3,72 18,14 3,72 18,14
5/64 2.0 4,64 22,68 4,64 22,68 4,64 22,68 4,64 22,68 4,64 22,68 4,64 22,68 4,64 22,68
3/32 2.4 5,57 27,22 5,57 27,22 5,57 27,22 5,57 27,22 5,57 27,22 5,57 27,22
1/8 3.2 7,43 36,29 7,43 36,29 7,43 36,29 7,43 36,29
5/32 4.0 9,29 45,36 9,29 45,36 9,29 45,36
3/16 4.8 11,15 54,43 11,15 54,43
7/32 5.6 13,01 63,50 13,01 63,50
1/4 6.4 14,86 72,58

Thickness
24" x 24"
(2Ft x 2Ft)
600x 600mm
24" x 36"
(2Ft x 3Ft)
600 x 900mm
24" x 48"
(2Ft x 4Ft)
600 x 1200mm
24" x 60"
(2Ft x 5Ft)
600 x 1500mm
24" x 72"
(2Ft x 6Ft)
600 x 1800mm
24" x 84"
(2Ft x 7Ft)
600x 2000mm
24" x 96"
(2 Ft x 8Ft)
600 x 2400mm
inch mm Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2
1/32 0.8 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07
5/128 1.0 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34
3/64 1.2 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61 2,79 13,61
1/16 1.6 3,72 18,14 3,72 18,14 3,72 18,14 3,72 18,14
5/64 2.0 4,64 22,68 4,64 22,68 4,64 22,68
3/32 2.4 5,57 27,22 5,57 27,22
1/8 3.2 7,43 36,29
5/32 4.0 9,29 45,36

Thickness
36" x 36"
(3Ft x 3Ft)
900x 900mm
36" x 48"
(3Ft x 4Ft)
900 x 1200mm
36" x 60"
(3Ft x 5Ft)
900 x 1500mm
36" x 72"
(3Ft x 6Ft)
900 x 1800mm
36" x 84"
(3Ft x 7Ft)
900 x 2000mm
36" x 96"
(3Ft x 8Ft)
900x 2400mm
inch mm Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2 Lbs/Ft2 Kg/m2
1/32 0.8 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9,07 1,86 9.07
5/128 1.0 2,32 11,34 2,32 11,34 2,32 11,34 2,32 11,34
3/64 1.2 2,79 13,61 2,79 13,61 2,79 13,61
1/16 1.6 3,72 18,14


Above weights are based on Pure Lead (99.97% Min.) Other sizes available upon request


X-RAY

It is a well-known fact that X-Rays, unless properly controlled and directed, are very harmful to the human body and have even been known to cause death. As a consequence, various materials are being utilizes for the insulating of the X-Ray tubes. There are two general methods of securing this protection. One is by the use of protective plasters, such as barium sulphate plaster, and the other is the use of sheet lead. In the use of plaster there are couple of disadvantages. But sheet lead has none of these disadvantages and is consequently considered the best possible protection. The Advisory Committee on X-Ray Protection of the International Congress of Radiology specifically warns against the use of protective plasters in installations of over 75 kV.The thickness of lead required varies with the power of the X-Ray apparatus. 


The thickness recommended by the Second International Congress of Radiology are presented in the accompanying table:


Recommended Thickness of Lead Shielding for X-Ray Rooms



X-Rays generated by peak voltages not exceeding Minimum thickness of Lead Weight
(Kg/ m2)
(mm) (Inch)
75 kV 1.0 0.039 9.86
100 kV 1.5 0.059 19.7
125 kV 2.0 0.079 24.6
150 kV 2.5 0.098 34.5
175 kV 3.0 0.118 39.4
200 kV 4.0 0.157 49.3
225 kV 5.0 0.197 64.1
300 kV 9.0 0.354 118.4
400 kV 15.0 0.591 187.5
500 kV 22.0 0.369 276.3
600 kV 34.0 1.343 399.7
900 kV 51.0 2.000 592.1


Required Lead Shielding Thickness for Gamma Rays

The table below, prepared by the American National Bureau of Standards, is frequently used in determining the thickness of lead needed for shielding from gamma ray sources in laboratories.


Energy (Mev- 1 million electron-volts.)
Activity 0.2 0.5 0.8 1.0 1.5 2.0 2.5 3.0 4.0
10 mc -0.14 -0.36 -0.27 -0.11 +0.37 +0.78 +1.15 +1.40 +1.70
20 mc -0.09 +0.00 +0.41 +0.76 +1.57 +2.16 +2.63 +2.91 +3.21
50 mc -0.01 +0.47 +1.31 +1.90 +3.15 +4.00 +4.57 +4.90 +5.20
100 mc +0.06 +0.82 +1.99 +2.77 +4.34 +5.38 +6.05 +6.41 +6.71
200 mc +0.10 +1.17 +2.67 +3.63 +5.54 +6.77 +7.52 +7.92 +8.21
500 mc +0.17 +1.64 +3.57 +4.78 +7.12 +8.60 +9.47 +9.91 +10.21
1 c +0.23 +1.99 +4.25 +5.65 +8.31 +9.99 +10.95 +11.41 +11.71
2 c +0.28 +2.35 +4.93 +6.52 +9.51 +11.37 +12.42 +12.92 +13.22
5 c +0.36 +2.81 +5.82 +7.66 +11.09 +13.21 +14.37 +14.91 +15.21
10 c +0.41 +3.17 +6.50 +8.52 +12.28 +14.59 +15.85 +16.42 +16.72
20 c +0.47 +3.52 +7.18 +9.39 +13.48 +15.98 +17.32 +17.93 +18.23
50 c +0.54 +3.99 +8.08 +10.54 +15.06 +17.81 +19.27 +19.92 +20.22
100 c +0.60 +4.34 +8.76 +11.40 +16.25 +19.20 +20.75 +21.43 +21.72
Danger Range Artı Artı Artı Artı Artı Artı Artı Artı Artı
20 cm +0.26 +1.64 +3.16 +4.02 +5.55 +6.44 +6.85 +7.00 +7.00
50 cm +0.11 +0.71 +1.36 +1.73 +2.39 +2.77 +2.95 +3.01 +3.01
1 M +0.00 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00
2 M -0.11 -0.71 -1.36 -1.73 -2.39 -2.77 -2.95 -3.01 -3.01
5 M -0.26 -1.64 -3.16 -4.02 -5.55 -6.44 -6.85 -7.00 -7.00
10 M -0.37 -2.35 -4.52 -5.76 -7.94 -9.21 -9.80 -10.01 -10.01
Working
time hr/day
Artı Artı Artı Artı Artı Artı Artı Artı Artı
1 -0.17 -1.06 -2.04 -2.60 -3.59 -4.16 -4.42 -4.52 -4.52
2 -0.11 -0.71 -1.36 -1.73 -2.39 -2.77 -2.95 -3.01 -3.01
4 -0.06 -0.35 -0.68 -0.87 -1.20 -1.39 -1.47 -1.51 -1.51
8 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00 +0.00
24 +0.09 +0.56 +1.08 +1.37 +1.89 +2.20 +2.34 +2.39 +2.3

SOUND PROOFING

Soundproofing is becoming ever more important because of the noise polluting our environment. Sheet lead is one of the basic materials for acoustic control systems, lead is an extremely efficient barrier material by itself or fastened to studs as part of a wall. Arslan Metal’s lead sheet products are widely used in different applications for sound proofing.

Below the table, lead for noise control compared to other materials



Material Thickness required in inches
(mm)
Moderately Noisy Office Quiet Office Very Quite Office
Plywood 0,932 1,694 3,335
Sand Plaster 0,050 1,130 2,260
Pine 0,033 2,387
Intensive Concrete 0,035 1,231 3,098
Aluminum 0,033 1,447 2,870
Steel 0,001 0,050 1,778
Lead 0,007 0,034 0,137
Arslan Metal Sanayi Tic. A.S
Arslan Metal Sanayi  Tic. A.S qrcode
Notify me of Innovation
  • fb.com/Arslan Metal Sanayi  Tic. A.S
  • instagram.com/Arslan Metal Sanayi  Tic. A.S
  • linkedin.com/Arslan Metal Sanayi  Tic. A.S
  • tw.co/Arslan Metal Sanayi  Tic. A.S
  • plus.google.com/Arslan Metal Sanayi  Tic. A.S
  • pinterest.com/Arslan Metal Sanayi  Tic. A.S
This web design, the site is an original design. Design is considered under the Law on Intellectual and Artistic Works and the design rights belong to the designer firm.